<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-01 16-41-05
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 61 kHz 14611 13,6678
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,6 dBr 4,80 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 61 kHz MIN: 11 kHz % above 76 kHz: 13,6678 Acquired: 2025/03/01 16.40.01 Total samples: 14611 Equivalent time: 0:12:10 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: 6,3 dBr MIN: 3,6 dBr AVE: 4,80 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2025/03/01 16.40.00) 16.26 16.28 16.30 16.32 16.34 16.36 16.38 16.40 0 2 4 6 Pm [dBr]